Developed in St. Petersburg, FloridaUltrasonic parts cleaner / 1 gallon

Field guide / 01

Before you
fill the tank.

A reliable result depends on the whole system: part, finish, chemistry, dilution, ultrasonic energy, temperature, time, rinse, drying, and protection.

1:9See final directionsInspect between cycles
Safety starts before chemistry.

Verify unloaded. Remove ammunition. Follow every applicable manufacturer. Use required eye and skin protection. Keep the product and working bath away from children.

08 A complete working sequence
  1. 01

    Clear and disassemble

    Verify the firearm is unloaded. Remove ammunition from the work area. Disassemble only as directed by the firearm, suppressor, part, and ultrasonic-equipment manufacturers.

  2. 02

    Inspect compatibility

    Identify the base material, coating, finish, adhesives, seals, and any hidden assemblies. Chemical compatibility and ultrasonic compatibility are separate questions; both must be acceptable.

  3. 03

    Prepare the bath

    The current process target is 1:9: one measured part concentrate plus nine measured parts clean water. Prepare only the amount needed for the tank and workload.

  4. 04

    Set the conditions

    Follow the final product directions and equipment guidance for bath temperature. Place parts in the basket without crowding, keep them off the tank floor, and ensure trapped air can escape.

  5. 05

    Run the shortest effective cycle

    Start with the shortest cycle permitted by the product and equipment directions, stop, and inspect. Reposition or repeat only when needed and when the part and finish permit it.

  6. 06

    Rinse and dry completely

    Remove the basket, let it drain, and rinse parts as directed. Dry every surface, bore, recess, and internal passage immediately using methods allowed by the part manufacturer.

  7. 07

    Restore protection

    Ultrasonic cleaning removes protective oil along with contamination. Immediately restore the exact lubrication or corrosion-protection system specified for the part before assembly or storage.

  8. 08

    Manage the used bath

    Track what entered the solution. Oils, lead, copper, carbon, and other removed material may determine storage and disposal requirements even when the unused concentrate has different classifications.

Field guide / 02

Build a modular
cleaning station.

Keep the main tank as the coupling bath, then suspend approved beakers or auxiliary pans for each job. You can move individual parts through the treatment they actually need while keeping soil and separate chemistries out of the main tank.

Use the ultrasonic cleaner manufacturer’s indirect-cleaning accessories when available. Flexible pouches are not part of this recommended setup; seam strength, chemical compatibility, temperature tolerance, and acoustic performance vary.

01Ready

Final rinse

Clean water

Use a dedicated vessel for the rinse specified by the product directions. Distilled or deionized water can help reduce mineral residue.

02Ready

Routine cleaning

Labeled 1:9 dilution

Use the standard working dilution for oil, powder residue, and routine fouling. For a lighter job, shorten the cycle and inspect instead of improvising a weaker mix.

03Ready

Heavy carbon

Inspect · brush · repeat

Start with the same labeled dilution. After a short cycle, spot-brush compatible stubborn deposits, reposition the part, and repeat only where needed.

One important boundary

“Full strength” can sound like undiluted concentrate. Use standard labeled dilution instead. Follow the product directions for concentration and use the shortest effective cycle for the actual part and finish.

06 High-value tank tactics

Small habits that improve repeatability without asking every part to tolerate a more aggressive process.

01

Degas every fresh bath

Run the machine’s prescribed degas cycle before adding parts. Entrained air weakens cavitation; many equipment manuals call for roughly 5–10 minutes, but your tank manual controls.

02

Suspend every vessel

Use the manufacturer’s basket, beaker holder, or auxiliary pan. Neither parts nor secondary containers should rest on the tank floor.

03

Make room for the sound

Several small, spaced loads usually work better than one crowded load. Keep precision surfaces from touching and leave a clear path for liquid circulation.

04

Release trapped air

Lower complex parts at an angle and orient cavities so bubbles can escape. Reposition between short cycles when blind holes or passages may be shielding contamination.

05

Track each assembly

Keep pins, springs, baffles, and small components together in a labeled fine-mesh basket. Do not mix parts from different firearms or assemblies.

06

Escalate only as needed

Start with the mildest approved process, inspect, then spot-brush or repeat a short cycle. Do not make every part endure the treatment required by the dirtiest one.

At-a-glance target

Your cleaning
reference card.

Dilution
1:9
Bath range
See final directions
Cycle
Inspect between cycles
After
Rinse · dry · protect

The approved product label controls. Confirm temperature and cycle settings against the final directions before use.